Intensiv Diamant Nr.8305 LP FG, 6 Stk.
23791
205
Riferimento: 68.708.306
Cylinder Diamond Instrument.
Proper use:
° The instrument shank must be inserted as deeply as possible into the chuck.
° Avoid jamming or levering actions when rotating, as this increases the risk of instrument breakage.
° Before applying the instrument to the workpiece, reach the required working speed.
° Use the instruments over the entire length of their working head and not just at the tip, so as to avoid an unconscious increase of the contact pressure causing local overheating.
° Never exceed the specified maximum speed, so as to avoid instrument breakage caused by the generation of powerful centrifugal forces. This occurs in particular when the diameter of the working head exceeds that of the shaft.
° Provide for adequate water irrigation (minimum 50 ml/min).
° In case of instruments exceeding ISO 027 provide additional waterspray cooling.
° Clean the instruments and remove debris after each use, so as to maintain their abrasive ability. We recommend to use the appropriate Intensiv Cleaning Rubber Diakleen.
Maintenance of Diamond Instruments?:
° Instruments are delivered non-sterile. They must be disinfected, cleaned, and sterilized prior to first use on the patient and immediately after each use.
Disinfection:
° Disinfect the diamond instruments separately from non-stainless steel instruments, such as polishers and abrasives.
° Use only cleaning/disinfection solutions that provide corrosion protection, and strictly observe the concentrations and reaction times recommended by the manufacturer.
° In case of heavily contaminated instruments it is advisable to use an ultrasonic bath.
Inspection/Cleaning:
° After disinfection, inspect?the instruments for residual contamination. If necessary, repeat the disinfection/cleaning procedure.
° Clean clogged diamond surfaces using the special Intensiv Cleaning Rubber Diakleen or a suitable brush. Thoroughly rinse the instruments with water and dry them immediately.
° Check for possible damages; dispose of oxydized, blunt and eccentric instruments.
Sterilization:
° Sterilization must be performed with validated procedures. If possible, use a single-pulsed or fractionated vacuum autoclave and subvacuum drying.
° Chemiclave sterilizers may also?be used. Hot air sterilizers are not suitable for diamond instruments.
° Avoid temperatures above 180° C which may affect the durability of the instruments.
° Concerning the sterilization process we refer to the ISO standard 17664; so we suggest to follow these advices:
Cycles at 134°C:
Tmin = 134°C Tmax = 138°C
Pressure = 3.15 bar abs
?Time = 4 min (raisable)?
Cycles at 121°C:
?Tmin = 121°C Tmax = 125°C
Pressure = 2.10 bar abs?
Time = 16 min (raisable)
General information: Keep the original package for the whole life cycle of the instrument, in order to ensure batch traceability.
Leggi di più
Proper use:
° The instrument shank must be inserted as deeply as possible into the chuck.
° Avoid jamming or levering actions when rotating, as this increases the risk of instrument breakage.
° Before applying the instrument to the workpiece, reach the required working speed.
° Use the instruments over the entire length of their working head and not just at the tip, so as to avoid an unconscious increase of the contact pressure causing local overheating.
° Never exceed the specified maximum speed, so as to avoid instrument breakage caused by the generation of powerful centrifugal forces. This occurs in particular when the diameter of the working head exceeds that of the shaft.
° Provide for adequate water irrigation (minimum 50 ml/min).
° In case of instruments exceeding ISO 027 provide additional waterspray cooling.
° Clean the instruments and remove debris after each use, so as to maintain their abrasive ability. We recommend to use the appropriate Intensiv Cleaning Rubber Diakleen.
Maintenance of Diamond Instruments?:
° Instruments are delivered non-sterile. They must be disinfected, cleaned, and sterilized prior to first use on the patient and immediately after each use.
Disinfection:
° Disinfect the diamond instruments separately from non-stainless steel instruments, such as polishers and abrasives.
° Use only cleaning/disinfection solutions that provide corrosion protection, and strictly observe the concentrations and reaction times recommended by the manufacturer.
° In case of heavily contaminated instruments it is advisable to use an ultrasonic bath.
Inspection/Cleaning:
° After disinfection, inspect?the instruments for residual contamination. If necessary, repeat the disinfection/cleaning procedure.
° Clean clogged diamond surfaces using the special Intensiv Cleaning Rubber Diakleen or a suitable brush. Thoroughly rinse the instruments with water and dry them immediately.
° Check for possible damages; dispose of oxydized, blunt and eccentric instruments.
Sterilization:
° Sterilization must be performed with validated procedures. If possible, use a single-pulsed or fractionated vacuum autoclave and subvacuum drying.
° Chemiclave sterilizers may also?be used. Hot air sterilizers are not suitable for diamond instruments.
° Avoid temperatures above 180° C which may affect the durability of the instruments.
° Concerning the sterilization process we refer to the ISO standard 17664; so we suggest to follow these advices:
Cycles at 134°C:
Tmin = 134°C Tmax = 138°C
Pressure = 3.15 bar abs
?Time = 4 min (raisable)?
Cycles at 121°C:
?Tmin = 121°C Tmax = 125°C
Pressure = 2.10 bar abs?
Time = 16 min (raisable)
General information: Keep the original package for the whole life cycle of the instrument, in order to ensure batch traceability.
INTENSIV
68.708.306
I clienti hanno anche comprato...
Filtek Supreme XTE Capsules, Body A3.5
Nanocomposito versatile, ad elevate prestazioni. Esteticamente eccellente per...
Kerr Temp Bond NE ohne, Modifier Art.60256 65 gr.
Questo cemento provvisorio, privo di eugenolo, non inibisce la...
Dentiro Sensitive Flächendesinfektion - 5 lt. Kanister CH-041025
DENTIRO® Sensitive ist ein voll viruzides Flächendesinfektionsmittel...
Articoli simili:
Intensiv Diamant FG 01440, 6 Stk.
Cylinder Diamond Instrument. Proper use: ° The instrument shank must be...
Intensiv Diamant Nr.9305L FG, 6 Stk.
Cylinder Diamond Instrument. Proper use: ° The instrument shank must be...
Diamendo FG Nr.2 25mm, 1 Stk., A016532500200
Zur Eröffnung des Wurzelkanals, ermöglicht einen geradlinigen Zugang. Nicht...