Flame Diamond Instrument.
Proper use:
° The instrument shank must be inserted as deeply as possible into the chuck.
° Avoid jamming or levering actions when rotating, as this increases the risk of instrument breakage.
° Before applying the instrument to the workpiece, reach the required working speed.
° Use the instruments over the entire length of their working head and not just at the tip, so as to avoid an unconscious increase of the contact pressure causing local overheating.
° Never exceed the specified maximum speed, so as to avoid instrument breakage caused by the generation of powerful centrifugal forces. This occurs in particular when the diameter of the working head exceeds that of the shaft.
° Provide for adequate water irrigation (minimum 50 ml/min).
° In case of instruments exceeding ISO 027 provide additional waterspray cooling.
° Clean the instruments and remove debris after each use, so as to maintain their abrasive ability. We recommend to use the appropriate Intensiv Cleaning Rubber Diakleen.
Maintenance of Diamond Instruments?:
° Instruments are delivered non-sterile. They must be disinfected, cleaned, and sterilized prior to first use on the patient and immediately after each use.
Disinfection:
° Disinfect the diamond instruments separately from non-stainless steel instruments, such as polishers and abrasives.
° Use only cleaning/disinfection solutions that provide corrosion protection, and strictly observe the concentrations and reaction times recommended by the manufacturer.
° In case of heavily contaminated instruments it is advisable to use an ultrasonic bath.
Inspection/Cleaning:
° After disinfection, inspect?the instruments for residual contamination. If necessary, repeat the disinfection/cleaning procedure.
° Clean clogged diamond surfaces using the special Intensiv Cleaning Rubber Diakleen or a suitable brush. Thoroughly rinse the instruments with water and dry them immediately.
° Check for possible damages; dispose of oxydized, blunt and eccentric instruments.
Sterilization:
° Sterilization must be performed with validated procedures. If possible, use a single-pulsed or fractionated vacuum autoclave and subvacuum drying.
° Chemiclave sterilizers may also?be used. Hot air sterilizers are not suitable for diamond instruments.
° Avoid temperatures above 180° C which may affect the durability of the instruments.
° Concerning the sterilization process we refer to the ISO standard 17664; so we suggest to follow these advices:
Cycles at 134°C:
Tmin = 134°C Tmax = 138°C
Pressure = 3.15 bar abs
?Time = 4 min (raisable)?
Cycles at 121°C:
?Tmin = 121°C Tmax = 125°C
Pressure = 2.10 bar abs?
Time = 16 min (raisable)
General information: Keep the original package for the whole life cycle of the instrument, in order to ensure batch traceability.
Plus
Proper use:
° The instrument shank must be inserted as deeply as possible into the chuck.
° Avoid jamming or levering actions when rotating, as this increases the risk of instrument breakage.
° Before applying the instrument to the workpiece, reach the required working speed.
° Use the instruments over the entire length of their working head and not just at the tip, so as to avoid an unconscious increase of the contact pressure causing local overheating.
° Never exceed the specified maximum speed, so as to avoid instrument breakage caused by the generation of powerful centrifugal forces. This occurs in particular when the diameter of the working head exceeds that of the shaft.
° Provide for adequate water irrigation (minimum 50 ml/min).
° In case of instruments exceeding ISO 027 provide additional waterspray cooling.
° Clean the instruments and remove debris after each use, so as to maintain their abrasive ability. We recommend to use the appropriate Intensiv Cleaning Rubber Diakleen.
Maintenance of Diamond Instruments?:
° Instruments are delivered non-sterile. They must be disinfected, cleaned, and sterilized prior to first use on the patient and immediately after each use.
Disinfection:
° Disinfect the diamond instruments separately from non-stainless steel instruments, such as polishers and abrasives.
° Use only cleaning/disinfection solutions that provide corrosion protection, and strictly observe the concentrations and reaction times recommended by the manufacturer.
° In case of heavily contaminated instruments it is advisable to use an ultrasonic bath.
Inspection/Cleaning:
° After disinfection, inspect?the instruments for residual contamination. If necessary, repeat the disinfection/cleaning procedure.
° Clean clogged diamond surfaces using the special Intensiv Cleaning Rubber Diakleen or a suitable brush. Thoroughly rinse the instruments with water and dry them immediately.
° Check for possible damages; dispose of oxydized, blunt and eccentric instruments.
Sterilization:
° Sterilization must be performed with validated procedures. If possible, use a single-pulsed or fractionated vacuum autoclave and subvacuum drying.
° Chemiclave sterilizers may also?be used. Hot air sterilizers are not suitable for diamond instruments.
° Avoid temperatures above 180° C which may affect the durability of the instruments.
° Concerning the sterilization process we refer to the ISO standard 17664; so we suggest to follow these advices:
Cycles at 134°C:
Tmin = 134°C Tmax = 138°C
Pressure = 3.15 bar abs
?Time = 4 min (raisable)?
Cycles at 121°C:
?Tmin = 121°C Tmax = 125°C
Pressure = 2.10 bar abs?
Time = 16 min (raisable)
General information: Keep the original package for the whole life cycle of the instrument, in order to ensure batch traceability.
INTENSIV
68.794.345
Non
Ja
Les clients ont également acheté
Wild Rosol "CE" avec fluor vert 1500 comprimés 10.6963
Comprimés effervescents pour bains de bouche rafraîchissants. Pour...
Luna Gold rouleaux de coton n°1 art.109121 300 gr.
Luna Gold est un rouleau salivaire unique vous voyez la différence. Luna...
Ampoules cylindriques de Rudocaïne 1.7 ml Art.D100155 100 pcs.
Wirkstoff: Articain, Adrenalin
Articles connexes:
Diamant conique long ellipse 5 pcs. 8868.314.016
Conique, à bout rond.
Diamant intensif n°191 FG 6 pces
Torpedo Diamond Instrument. Proper use: ° The instrument shank must be...
Diamant intensif Nr.315SC FG 6 pcs.
Cylinder Diamond Instrument. Proper use: ° The instrument shank must be...
Intensiv Proxoshape PS2
Prix par pièce